Liquid Controls · Hydraulics
48616
In stock · ships from Knoxville
This is a packing gland kit for Liquid Controls M-series positive displacement flow meters.
Confirm the part fits before you buy. Applications and interchange numbers are researched and audited per part.
Verified fitment for 4 applications
Add your truck to see whether it's one of them
All confirmed applications for this part number.
Other applications
Other applications
Fits fork-drive meter configurations. Verify your meter uses a fork drive and requires the 24-tooth gear style. An 8-tooth version exists under a different part number (e.g., 48617).
Part data verified against 5 catalog sources
Numbers this part supersedes or interchanges with. Showing 1 of 1.
Different year, make, or config? Get a confirmation against your truck in under a minute.
It seals the shaft where it exits the meter body to prevent product leakage. The kit includes a fork-drive gland with a 24-tooth gear, pinion gears for 1:1 and 2:1 ratios, a drive coupling for tapered rotor elements, and O‑rings/U‑cups available in Buna, Viton, or PTFE. Replace it when leakage appears at the packing gland, which commonly occurs from wear, temperature extremes, or the fluid being metered.
Part Number: 48616